reviewing QTI images at the consult desk

For physicians and providers

A radiation‑free, compression‑free
supplemental imaging option
for your patients

For women with dense breasts, implants, inconclusive findings, elevated risk under 40, or supplemental screening over 40. No formal referral is required, and reports can be delivered directly to your office with the patient's consent.

Contact the clinic

What we offer your patients

Native 3D imaging
from nipple to chest wall, read by
a board-certified radiologist

The QT Imaging Breast Acoustic CT scanner produces co-registered volumes of speed of sound, attenuation, and reflection at sub-millimeter resolution, viewable in coronal, axial, and sagittal planes. Software quantifies fibroglandular volume, total breast volume, and fibroglandular ratio for density assessment and monitoring.

The device is FDA 510(k)-cleared as a supplemental screening device for breast imaging, including follow-up of inconclusive findings, and for quantitative breast density assessment. It is not cleared to replace screening mammography, and we do not present it that way to patients.

Clinical summary

Modality
Quantitative Transmission ultrasound, native 3D, no ionizing radiation, no compression, no contrast
Resolution
Sub-millimeter, comparable to MRI, reproducible regardless of operator, breast size, or tissue type
Quantitative outputs
Fibroglandular volume, total breast volume, fibroglandular ratio
FDA status
510(k)-cleared supplemental screening device, including follow-up of inconclusive findings, and quantitative breast density assessment
Interpretation
Board-certified radiologist trained in QT imaging; report delivered securely to the patient and, with consent, to your office
Patient criteria
Women 18 and older, breast sizes to DDD, body weight to 400 lb; call first for pregnancy, breastfeeding, recent biopsy site or open skin, magnetic implants, or adhesive, chlorine, or alcohol allergy
Scan time
Roughly 10 to 20 minutes per breast; about one hour on site

For physicians

Clinical advantages
of QTI imaging

QTI is a breakthrough in breast imaging. QT imaging is the only FDA‑cleared device that combines transmission and reflection imaging, using low‑frequency sound waves to image the whole breast safely, from nipple to chest wall. Because the scan is safe to repeat, serial studies allow radiologists to assess change over time, including the growth rate of a lesion.

01

Dense breast tissue

In dense breasts, QTI images visualize ductal and glandular tissue with high accuracy when compared with conventional imaging using X‑ray mammography (XRM) and handheld ultrasound (HHUS).

02

Accuracy compared with XRM

Improved accuracy, sensitivity, and specificity when compared with XRM.

03

Fewer non‑cancer recalls

Improves the non‑cancer recall rate without substantially affecting cancer recall rates.

04

Treatment follow‑up and density

Can follow patients through cancer treatment and provides quantitative breast density measurements, including enhanced volume measurements.

05

Not operator dependent

Image acquisition is not scanner operator dependent, supporting consistent, reproducible studies.

06

Fine detail

A clinical feature detects findings in the 50 to 100 micron range, including microcalcifications.

Supporting clinical references are available on request.

Imaging around implants

Implant‑associated cancers

Because the scan uses transmitted sound with no compression, the tissue surrounding a silicone implant remains readable. In these speed‑of‑sound images, both lobular and ductal carcinomas are clearly visible with the implant in place.

QTI speed of sound image showing lobular carcinoma beside a silicone implant
QTI speed of sound image showing ductal carcinoma with a silicone implant, first view
QTI speed of sound image showing ductal carcinoma with a silicone implant, second view

Lobular carcinoma

Ductal carcinoma

Speed‑of‑sound images. Courtesy of QT Imaging, Inc.

Referring a patient

No formal referral required

Patients can book directly, or your office can contact us to coordinate scheduling and report delivery. Scans are $750 bilateral or $550 unilateral, paid at booking, with a CPT code provided for patients who wish to submit to their insurance, so there is no prior authorization to manage.

If you would like to visit the clinic, see the scanner, or discuss the published research behind QT imaging, we would be happy to answer your questions.

Contact the clinic
the lounge beneath the Clear Breast wall logo
FDA 510(k) ClearedQT Imaging TechnologyBoard-Certified RadiologistsNo Referral Needed